How to Place an Above-Ground Termite Bait Station Over Active Workings
Placing an above-ground termite bait station correctly is essential when termites are already feeding in accessible timber or building areas. The Demise Above-Ground Termite Bait Station is designed to sit directly over active termite workings or a confirmed feeding area, creating a contained location for approved bait and ongoing monitoring.
At a glance
Place Over Activity
Position the station directly over confirmed termite workings or a current feeding area.
Fix It Securely
Secure it carefully without unnecessarily disturbing termites or damaged timber.
Follow Bait Directions
Use only approved bait and follow the applicable label and treatment plan.
Close the Lid
Keep the lid closed to help maintain a dark environment inside the station.
Monitor Regularly
Inspect regularly to monitor feeding and maintain bait levels as required.
Confirm the active feeding site
Begin with a careful inspection. Look for live termites, shelter tubes, damaged timber, or visible workings that indicate current activity. The station should not be positioned simply because an area appears vulnerable; it is intended for a known or strongly indicated feeding location.
Choose a site that can be reached for inspection without regularly disturbing the timber or termite workings. If the activity is concealed, do not remove building materials or damage the structure merely to install a station. A qualified pest professional can determine whether the area is suitable and whether additional treatment is required.
Position the station over the workings
Place the station directly over the active workings or feeding area. The aim is to give termites access to the station at the point where they are already feeding, rather than relying on them to discover a remote location.
The station may be used on accessible infested timber or another suitable surface associated with the active workings. Keep the placement as close and direct as practical, while ensuring the station can remain stable and be inspected later.
Secure it without unnecessary disturbance
Affix the station securely to the infested timber or other suitable surface using an appropriate fixing method. A stable installation helps keep the station aligned with the feeding site and reduces the chance of movement during inspections or normal use of the area.
Work carefully around active termites. Avoid scraping away workings, breaking shelter tubes, or repeatedly opening the area while fitting the station. Unnecessary disturbance can interrupt feeding and make monitoring less useful.
Add approved bait correctly
The station forms part of the TERM-seal DEMISE termite monitoring and baiting system. Available product information identifies TERM-seal’s Abide termite bait as the bait used with the system, but the station itself should not be treated as a standalone chemical treatment.
Add bait only in accordance with the applicable product label and the treatment plan. Use the correct product, quantity, preparation method, and safety procedure for the current label. Do not substitute an unapproved insecticide or assume that bait supplied for another system is compatible.
If the treatment plan calls for an activity attractant or monitor before bait is introduced, follow that plan rather than adding bait prematurely. The purpose of the station is to support targeted feeding and observation at the active site.
Close the lid securely
After positioning the approved bait, close the station securely. A closed station helps maintain a dark environment inside, which supports continued termite feeding and keeps the bait contained.
Check that the lid is properly seated and that the station has not shifted away from the workings. Avoid leaving the station open between inspections, and keep termite bait away from children, pets, food, and food-preparation areas.
Inspect and maintain the station
Above-ground bait stations require regular inspection. Check whether termites remain active, whether feeding is continuing, and whether bait needs to be replenished or replaced. Inspection frequency should follow the treatment plan and the directions for the bait being used.
Keep inspections as gentle and brief as possible. Record changes in activity and bait condition so treatment progress can be assessed over time. Do not assume that a quiet station proves the infestation has been eliminated; reduced activity may require professional interpretation and further inspection.
Use it as part of a wider plan
An above-ground station is a targeted tool for active termite workings, not a replacement for a complete termite inspection. The source of the infestation, concealed entry points, moisture conditions, timber damage, and other activity around the building may still need attention.
The Demise station is intended for informed or professional use as part of a planned termite management program. Follow the bait label, maintain the station as directed, and seek qualified advice when the workings cannot be safely accessed, the extent of activity is unclear, or structural timber may be compromised.